Table 6 Spearman correlation between dose metrics calculated based on scintigraphic or MRI contourings, in patients receiving resin microspheres (n = 25) and glass microspheres (n = 23)

From: Impact of contouring methods on pre-treatment and post-treatment dosimetry for the prediction of tumor control and survival in HCC patients treated with selective internal radiation therapy

 

Scintigraphic-based contours

MRI-based contours

Resin microspheres (n = 25)

Glass microspheres (n = 23)

r

p

r

p

Pre-treatment dose metrics

Dm-Pre-CSPECT

Dm-Pre-CMRI

0.70

0.0001

0.71

0.0002

 

D70-Pre-CSPECT

D70-Pre-CMRI

0.22

NS

0.47

0.02

Post-treatment dose metrics

Dm-Post-CPET

Dm-Post-CMRI

0.76

< 0.0001

0.54

0.007

 

D70-Post-CPET

D70-Post-CMRI

0.49

0.01

0.15

NS