Skip to main content

Table 1 Extraction efficiency of [18F, natGa]rhPSMA-7 from blood, liver, kidney and tumor.

From: Preclinical comparison of four [18F, natGa]rhPSMA-7 isomers: influence of the stereoconfiguration on pharmacokinetics

 

Tissues

Efficiency [% Extracted radioactivity]

Sample extraction

SPE purification

Overall

Potter–Elvehjem

tissue grinder (n = 1)

Kidney

91

66

60

Tumor

90

59

53

MM-400 ball mill

(n = 3)

Liver

97

89 ± 2

86 ± 2

Kidney

63 ± 5

68 ± 8

43 ± 8

Tumor

64 ± 18

65 ± 3

42 ± 14

 

Blood (n = 4)

97 ± 2

94 ± 2

90 ± 4

  1. Samples were extracted using either a Potter–Elvehjem tissue grinder (n = 1) or a MM-400 Ball Mill (n = 3). The percentage of activity after sample extraction and after SPE purification was quantified, decay-corrected, and the overall extracted activity was calculated (values are expressed as mean ± SD).