Skip to main content

Table 4 Kinetic parameters of the modelling study

From: Dispersion-corrected extracorporeal arterial input functions in PET studies of mice: a comparison to intracorporeal microprobe measurements

Model

Parameter

Simulated value

Fitted value using \(AI{F}_{DG}\)

Fitted value using \(AI{F}_{SG}\)

\({\chi }_{DG}^{2}\)

\({\chi }_{SG}^{2}\)

1TC-sim1

\({v}_{B}\)

0.050

0.057 ± 0.014

0.056 ± 0.023

0.899 ± 1.341

0.800 ± 1.302

\({K}_{1}\)(min−1)

0.200

0.179 ± 0.025

0.177 ± 0.025

\({k}_{2}\)(min−1)

0.100

0.093 ± 0.010

0.093 ± 0.009

\({V}_{T}\)

2.000

1.932 ± 0.179

1.910 ± 0.184

1TC-sim2

\({v}_{B}\)

0.050

0.050 ± 0.028

0.0517 ± 0.024

0.062 ± 0.092

0.029 ± 0.025

\({K}_{1}\)(min−1)

0.200

0.182 ± 0.020

0.185 ± 0.018

\({k}_{2}\)(min−1)

0.020

0.018 ± 0.002

0.019 ± 0.002

\({V}_{T}\)

10.00

10.135 ± 1.296

9.994 ± 1.136

2TC-sim1

\({v}_{B}\)

0.050

0.052 ± 0.006

0.045 ± 0.019

0.211 ± 0.304

0.093 ± 0.163

\({K}_{1}\)(min−1)

0.270

0.258 ± 0.047

0.253 ± 0.040

\({k}_{2}\)(min−1)

0.570

0.600 ± 0.055

0.591 ± 0.045

\({k}_{3}\)(min−1)

0.080

0.084 ± 0.012

0.083 ± 0.045

\({k}_{4}\)(min−1)

0.018

0.016 ± 0.003

0.017 ± 0.002

\({K}_{i}\)(min−1)

0.033

0.031 ± 0.002

0.031 ± 0.003

2TC-sim2

\({v}_{B}\)

0.050

0.039 ± 0.007

0.038 ± 0.016

0.014 ± 0.0169

0.023 ± 0.026

\({K}_{1}\)(min−1)

0.140

0.136 ± 0.026

0.136 ± 0.024

\({k}_{2}\)(min−1)

0.190

0.217 ± 0.039

0.221 ± 0.042

\({k}_{3}\)(min−1)

0.070

0.078 ± 0.039

0.077 ± 0.042

\({k}_{4}\)(min−1)

0.005

0.004 ± 0.002

0.004 ± 0.002

\({K}_{i}\)(min−1)

0.038

0.036 ± 0.003

0.035 ± 0.003

  1. Simulated and modelled parameters along with goodness-of-fits \({\chi }^{2}\) for the investigated compartment models using \(AI{F}_{DG}\) and \(AI{F}_{SG}\), presented as mean ± SD