Skip to main content

Table 3 The uncertainty u(D), Lin’s concordance correlation coefficient ρC and the normalized error EN for the simplified dosimetry protocols for the kidneys

From: Optimization of the radiation dosimetry protocol in Lutetium-177-PSMA therapy: toward clinical implementation

Method

u(D) (%)

ρC

EN

1 h

17.3 ± 0.1

0.48

2.23 ± 1.43

24 h

14.3 ± 0.3

0.94

0.73 ± 0.87

48 h

12.3 ± 0.1

0.80

0.99 ± 0.80

72 h

12.7 ± 0.1

0.85

1.06 ± 0.25

168 h

27.5 ± 3.9

0.75

1.63 ± 1.42

1 h + 168 h

11.6 ± 0.1

0.65

2.03 ± 1.92

24 h + 168 h

11.4 ± 0.1

0.97

0.44 ± 0.51

48 h + 168 h

11.3 ± 0.1

0.73

1.58 ± 0.22

72 h + 168 h

11.2 ± 0.1

0.43

2.64 ± 0.32

  1. Mean ± SD values are given. Parameters that meet requirements are marked in bold. Protocols where all parameters meet requirements are marked in bolditalics