Skip to main content

Table 6 Results of the receiver operating characteristic (ROC) curve analysis

From: Dynamic planar scintigraphy for the rapid kinetic measurement of myocardial 123I-MIBG turnover can identify Lewy body disease

 

AUC

95% CI

Cut-off

Sensitivity

95% CI

Specificity

95% CI

iUp/iLoss

0.8784*

0.8176–0.9391

3.769

0.9143

0.8451–0.9543

0.8197

0.7053–0.8962

iLoss

0.9029*

0.8521–0.9537

0.0436

0.8762

0.7996–0.9262

0.8361

0.7239–0.9084

eHMR

0.8631

0.8011–0.9251

2.042

0.8571

0.7776–0.9115

0.8361

0.7239–0.9084

(dHMR)

0.8924

0.8349–0.9500

1.720

0.8476

0.7667–0.9040

0.9344

0.8432–0.9742

(WR)

0.9085

0.8572–0.9598

0.3485

0.8571

0.7776–0.9115

0.9016

0.8016–0.9541

  1. A total of 166 patients were included. Indices enclosed in parentheses cannot be obtained in 30 min. Asterisks denote significant differences (*: P < 0.05) detected by the bootstrap test versus the AUC of eHMR. The cut-off values are those that yield the largest Youden’s index