Skip to main content

Table 5 Comparison of dose metrics based on scintigraphic contours and MRI contouring in patients receiving resin and glass microspheres

From: Impact of contouring methods on pre-treatment and post-treatment dosimetry for the prediction of tumor control and survival in HCC patients treated with selective internal radiation therapy

 

Resin microspheres (n = 25)

Glass microspheres (n = 23)

Scintigraphic-based contours

MRI-based contours

p

Scintigraphic-based contours

MRI-based contours

p

D70-Pre-(CSPECT and CMRI) (Gy)

82 [48–106]

68 [32–84]

NS

100 [71–123]

91 [40–148]

NS

Dm-Pre-(CSPECT and CMRI) (Gy)

137 [69–172]

115 [108–204]

NS

150 [107–205]

153 [97–241]

NS

D70-Post-(CPET and CMRI) (Gy)

52 [34–96]

39 [19–80]

NS

121 [102–166]

98 [37–202]

NS

Dm-Post-(CPET and CMRI) (Gy)

79 [55–150]

98 [50–130]

NS

197 [150–264]

156 [94–331]

NS

  1. All values are median (Q1–Q3). p values are based on Wilcoxon test