Skip to main content

Table 3 Median differences in parameters estimated from simulation study

From: Plasma radio-metabolite analysis of PET tracers for dynamic PET imaging: TLC and autoradiography

Parameter

K1 (mL min−1 g−1)

k2 (min−1)

k3 (min−1)

k4 (min−1)

Vp (ml g−1)

DV (ml g−1)

W (min)

Median difference

0.003

− 0.124

0.111

− 0.052

0.004

0.806

0.021

P

0.75

0.004

0.005

0.004

0.013

0.004

0.083

Bias (%)a

198.3

− 32.7

115.4

− 390.3

109.2

81.2

181.0

  1. Median differences between parameters in Table 1 estimated using AIF with and without metabolite correction. P value is estimated by nonparametric paired test
  2. aAlthough the differences in the estimated parameters were not normally distributed, the percentage bias was used to approximate the expected error