Skip to main content

Table 3 The average mass (n = 3, 1σ) of contaminant metals measured in the digestant and the eluate recovered from the AG MP-50 and CHELEX 100 resin

From: Photonuclear production, chemistry, and in vitro evaluation of the theranostic radionuclide 47Sc

Sample

Cr

Cu

Fe

Ni

Zn

Digestant mass (μg)

552 (30)

493 (72)

946 (35)

206 (24)

908 (620)

Post AG MP-50 (μg)

3.9 (0.3)

3.8 (0.7)

8.4 (1.8)

2.0 (0.6)

13 (6)

Post CHELEX 100 (μg)

0.6 (0.2)

0.8 (0.2)

1.8 (0.8)

0.5 (0.2)

1.9 (0.1)