TY - JOUR AU - Radon, J. PY - 1986 DA - 1986// TI - On the determination of functions from their integral values along certain manifolds JO - IEEE Trans Med Imaging VL - 5 UR - https://doi.org/10.1109/TMI.1986.4307775 DO - 10.1109/TMI.1986.4307775 ID - Radon1986 ER - TY - JOUR AU - Rockmore, A. J. AU - Macovski, A. PY - 1976 DA - 1976// TI - A maximum likelihood approach to emission image reconstruction from projections JO - IEEE Trans Nucl Sci VL - 23 UR - https://doi.org/10.1109/TNS.1976.4328496 DO - 10.1109/TNS.1976.4328496 ID - Rockmore1976 ER - TY - JOUR AU - Shepp, L. A. AU - Vardi, Y. PY - 1982 DA - 1982// TI - Maximum likelihood reconstruction for emission tomography JO - IEEE Trans Med Imaging VL - 1 UR - https://doi.org/10.1109/TMI.1982.4307558 DO - 10.1109/TMI.1982.4307558 ID - Shepp1982 ER - TY - JOUR AU - Shepp, L. A. AU - Vardi, Y. AU - Ra, J. B. AU - Hilal, S. K. AU - Cho, Z. H. PY - 1984 DA - 1984// TI - Maximum likelihood PET with real data JO - IEEE Trans Nucl Sci VL - 31 UR - https://doi.org/10.1109/TNS.1984.4333398 DO - 10.1109/TNS.1984.4333398 ID - Shepp1984 ER - TY - JOUR AU - Boellaard, R. AU - van Lingen, A. AU - Lammertsma, A. A. PY - 2001 DA - 2001// TI - Experimental and clinical evaluation of iterative reconstruction (OSEM) in dynamic PET: quantitative characteristics and effects on kinetic modeling JO - J Nucl Med VL - 42 ID - Boellaard2001 ER - TY - JOUR AU - Johnson, C. A. AU - Seidel, J. AU - Carson, R. E. AU - Gandler, W. R. AU - Sofer, A. AU - Green, M. V. PY - 1997 DA - 1997// TI - Evaluation of 3D reconstruction algorithms for a small animal PET camera JO - IEEE Trans Nucl Sci VL - 44 UR - https://doi.org/10.1109/23.597005 DO - 10.1109/23.597005 ID - Johnson1997 ER - TY - JOUR AU - Tsoumpas, C. AU - Turkheimer, F. E. AU - Thielemans, K. PY - 2008 DA - 2008// TI - Study of direct and indirect parametric estimation methods of linear models in dynamic positron emission tomography JO - Med Phys VL - 35 UR - https://doi.org/10.1118/1.2885369 DO - 10.1118/1.2885369 ID - Tsoumpas2008 ER - TY - JOUR AU - Hudson, H. M. AU - Larkin, R. S. PY - 1994 DA - 1994// TI - Accelerated image reconstruction using ordered subsets of projection data JO - IEEE Trans Med Imaging VL - 13 UR - https://doi.org/10.1109/42.363108 DO - 10.1109/42.363108 ID - Hudson1994 ER - TY - JOUR AU - Qi, J. AU - Leahy, R. M. PY - 2006 DA - 2006// TI - Iterative reconstruction techniques in emission computed tomography JO - Phys Med Biol VL - 51 UR - https://doi.org/10.1088/0031-9155/51/15/R01 DO - 10.1088/0031-9155/51/15/R01 ID - Qi2006 ER - TY - JOUR AU - Ahn, S. AU - Fessler, J. A. PY - 2003 DA - 2003// TI - Globally convergent image reconstruction for emission tomography using relaxed ordered subsets algorithms JO - IEEE Trans Med Imaging VL - 22 UR - https://doi.org/10.1109/TMI.2003.812251 DO - 10.1109/TMI.2003.812251 ID - Ahn2003 ER - TY - JOUR AU - Liow, J. S. AU - Strother, S. C. PY - 1991 DA - 1991// TI - Practical tradeoffs between noise, quantitation, and number of iterations for maximum likelihood-based reconstructions JO - IEEE Trans Med Imaging VL - 10 UR - https://doi.org/10.1109/42.108591 DO - 10.1109/42.108591 ID - Liow1991 ER - TY - JOUR AU - Etchebehere, E. C. AU - Macapinlac, H. A. AU - Gonen, M. AU - Humm, K. AU - Yeung, H. W. AU - Akhurst, T. PY - 2002 DA - 2002// TI - Qualitative and quantitative comparison between images obtained with filtered back projection and iterative reconstruction in prostate cancer lesions of (18)F-FDG PET JO - Q J Nucl Med VL - 46 ID - Etchebehere2002 ER - TY - JOUR AU - Lonneux, M. AU - Borbath, I. AU - Bol, A. AU - Coppens, A. AU - Sibomana, M. AU - Bausart, R. PY - 1999 DA - 1999// TI - Attenuation correction in whole-body FDG oncological studies: the role of statistical reconstruction JO - Eur J Nucl Med VL - 26 UR - https://doi.org/10.1007/s002590050426 DO - 10.1007/s002590050426 ID - Lonneux1999 ER - TY - JOUR AU - Krak, N. C. AU - Boellaard, R. AU - Hoekstra, O. S. AU - Twisk, J. W. AU - Hoekstra, C. J. AU - Lammertsma, A. A. PY - 2005 DA - 2005// TI - Effects of ROI definition and reconstruction method on quantitative outcome and applicability in a response monitoring trial JO - Eur J Nucl Med Mol Imaging VL - 32 UR - https://doi.org/10.1007/s00259-004-1566-1 DO - 10.1007/s00259-004-1566-1 ID - Krak2005 ER - TY - JOUR AU - Vriens, D. AU - Visser, E. P. AU - de Geus-Oei, L. F. AU - Oyen, W. J. PY - 2010 DA - 2010// TI - Methodological considerations in quantification of oncological FDG PET studies JO - Eur J Nucl Med Mol Imaging VL - 37 UR - https://doi.org/10.1007/s00259-009-1306-7 DO - 10.1007/s00259-009-1306-7 ID - Vriens2010 ER - TY - JOUR AU - Liow, J. S. AU - Strother, S. C. PY - 1993 DA - 1993// TI - The convergence of object dependent resolution in maximum likelihood based tomographic image reconstruction JO - Phys Med Biol VL - 38 UR - https://doi.org/10.1088/0031-9155/38/1/005 DO - 10.1088/0031-9155/38/1/005 ID - Liow1993 ER - TY - JOUR AU - Geman, S. AU - Geman, D. PY - 1984 DA - 1984// TI - Stochastic relaxation, Gibbs distributions, and the Bayesian restoration of images JO - IEEE Trans Pattern Anal Mach Intell VL - 6 UR - https://doi.org/10.1109/TPAMI.1984.4767596 DO - 10.1109/TPAMI.1984.4767596 ID - Geman1984 ER - TY - BOOK PY - 1985 DA - 1985// TI - Bayesian image analysis methods: an application to single photon emission computed tomography ID - ref18 ER - TY - JOUR AU - Mumcuoglu, E. U. AU - Leahy, R. M. AU - Cherry, S. R. PY - 1996 DA - 1996// TI - Bayesian reconstruction of PET images: methodology and performance analysis JO - Phys Med Biol VL - 41 UR - https://doi.org/10.1088/0031-9155/41/9/015 DO - 10.1088/0031-9155/41/9/015 ID - Mumcuoglu1996 ER - TY - BOOK PY - 2007 DA - 2007// TI - Analysis of organ uniformity in low count density penalized likelihood PET images ID - ref20 ER - TY - JOUR AU - Ahn, S. AU - Ross, S. G. AU - Asma, E. AU - Miao, J. AU - Jin, X. AU - Cheng, L. PY - 2015 DA - 2015// TI - Quantitative comparison of OSEM and penalized likelihood image reconstruction using relative difference penalties for clinical PET JO - Phys Med Biol VL - 60 UR - https://doi.org/10.1088/0031-9155/60/15/5733 DO - 10.1088/0031-9155/60/15/5733 ID - Ahn2015 ER - TY - JOUR AU - Chlewicki, W. AU - Hermansen, F. AU - Hansen, S. B. PY - 2004 DA - 2004// TI - Noise reduction and convergence of Bayesian algorithms with blobs based on the Huber function and median root prior JO - Phys Med Biol VL - 49 UR - https://doi.org/10.1088/0031-9155/49/20/004 DO - 10.1088/0031-9155/49/20/004 ID - Chlewicki2004 ER - TY - BOOK PY - 2012 DA - 2012// TI - Accurate and consistent lesion quantitation with clinically acceptable penalized likelihood images ID - ref23 ER - TY - JOUR AU - Teoh, E. J. AU - McGowan, D. R. AU - Macpherson, R. E. AU - Bradley, K. M. AU - Gleeson, F. V. PY - 2015 DA - 2015// TI - Phantom and clinical evaluation of the Bayesian penalized likelihood reconstruction algorithm Q.Clear on an LYSO PET/CT system JO - J Nucl Med VL - 56 UR - https://doi.org/10.2967/jnumed.115.159301 DO - 10.2967/jnumed.115.159301 ID - Teoh2015 ER - TY - JOUR AU - Sah, B. R. AU - Stolzmann, P. AU - Delso, G. AU - Wollenweber, S. D. AU - Hullner, M. AU - Hakami, Y. A. PY - 2017 DA - 2017// TI - Clinical evaluation of a block sequential regularized expectation maximization reconstruction algorithm in 18F-FDG PET/CT studies JO - Nucl Med Commun VL - 38 UR - https://doi.org/10.1097/MNM.0000000000000604 DO - 10.1097/MNM.0000000000000604 ID - Sah2017 ER - TY - JOUR AU - Bertolli, O. AU - Eleftheriou, A. AU - Cecchetti, M. AU - Camarlinghi, N. AU - Belcari, N. AU - Tsoumpas, C. PY - 2016 DA - 2016// TI - PET iterative reconstruction incorporating an efficient positron range correction method JO - Phys Med VL - 32 UR - https://doi.org/10.1016/j.ejmp.2015.11.005 DO - 10.1016/j.ejmp.2015.11.005 ID - Bertolli2016 ER - TY - JOUR AU - Fendler, W. P. AU - Eiber, M. AU - Beheshti, M. AU - Bomanji, J. AU - Ceci, F. AU - Cho, S. PY - 2017 DA - 2017// TI - (68)Ga-PSMA PET/CT: joint EANM and SNMMI procedure guideline for prostate cancer imaging: version 1.0 JO - Eur J Nucl Med Mol Imaging VL - 44 UR - https://doi.org/10.1007/s00259-017-3670-z DO - 10.1007/s00259-017-3670-z ID - Fendler2017 ER - TY - JOUR AU - Boellaard, R. AU - Quick, H. H. PY - 2015 DA - 2015// TI - Current image acquisition options in PET/MR JO - Semin Nucl Med VL - 45 UR - https://doi.org/10.1053/j.semnuclmed.2014.12.001 DO - 10.1053/j.semnuclmed.2014.12.001 ID - Boellaard2015 ER - TY - STD TI - Huang S-y, Savic D, Yang J, Shrestha U, Seo Y. The effect of magnetic field on positron range and spatial resolution in an integrated whole-body time-of-flight PET/MRI system. IEEE Nucl Sci Symp Conf Rec. 2014;2014 https://doi.org/10.1109/NSSMIC.2014.7431006. ID - ref29 ER - TY - JOUR AU - Levin, C. AU - Glover, G. AU - Deller, T. AU - McDaniel, D. AU - Peterson, W. AU - Maramraju, S. H. PY - 2013 DA - 2013// TI - Prototype time-of-flight PET ring integrated with a 3T MRI system for simultaneous whole-body PET/MR imaging JO - J Nucl Med Meeting Abstracts VL - 54 ID - Levin2013 ER - TY - JOUR AU - Gandhi, H. AU - Holley, D. AU - Gulaka, P. AU - Iagaru, A. PY - 2017 DA - 2017// TI - 68Ga-PSMA 11 PET/MRI influence of acquisition time on image quality JO - J Nucl Med VL - 58 ID - Gandhi2017 ER - TY - JOUR AU - Wollenweber, S. D. AU - Ambwani, S. AU - Lonn, A. H. R. AU - Shanbhag, D. D. AU - Thiruvenkadam, S. AU - Kaushik, S. PY - 2013 DA - 2013// TI - Comparison of 4-class and continuous fat/water methods for whole-body, MR-based PET attenuation correction JO - IEEE Trans Nucl Sci VL - 60 UR - https://doi.org/10.1109/TNS.2013.2278759 DO - 10.1109/TNS.2013.2278759 ID - Wollenweber2013 ER - TY - JOUR AU - Nuyts, J. AU - Beque, D. AU - Dupont, P. AU - Mortelmans, L. PY - 2002 DA - 2002// TI - A concave prior penalizing relative differences for maximum-a-posteriori reconstruction in emission tomography JO - IEEE Trans Nucl Sci VL - 49 UR - https://doi.org/10.1109/TNS.2002.998681 DO - 10.1109/TNS.2002.998681 ID - Nuyts2002 ER - TY - JOUR AU - Nuyts, J. AU - Michel, C. AU - Brepoels, L. AU - De Ceuninck, L. AU - Deroose, C. AU - Goffin, K. PY - 2009 DA - 2009// TI - Performance of MAP reconstruction for hot lesion detection in whole-body PET/CT: an evaluation with human and numerical observers JO - IEEE Trans Med Imaging VL - 28 UR - https://doi.org/10.1109/TMI.2008.927349 DO - 10.1109/TMI.2008.927349 ID - Nuyts2009 ER - TY - JOUR AU - Karp, J. S. AU - Surti, S. AU - Daube-Witherspoon, M. E. AU - Muehllehner, G. PY - 2008 DA - 2008// TI - Benefit of time-of-flight in PET: experimental and clinical results JO - J Nucl Med VL - 49 UR - https://doi.org/10.2967/jnumed.107.044834 DO - 10.2967/jnumed.107.044834 ID - Karp2008 ER - TY - JOUR AU - Laffon, E. AU - Lamare, F. AU - de Clermont, H. AU - Burger, I. A. AU - Marthan, R. PY - 2014 DA - 2014// TI - Variability of average SUV from several hottest voxels is lower than that of SUVmax and SUVpeak JO - Eur Radiol VL - 24 UR - https://doi.org/10.1007/s00330-014-3222-x DO - 10.1007/s00330-014-3222-x ID - Laffon2014 ER - TY - JOUR AU - de Pierro, A. R. AU - Beleza Yamagishi, M. E. PY - 2001 DA - 2001// TI - Fast EM-like methods for maximum “a posteriori” estimates in emission tomography JO - IEEE Trans Med Imaging VL - 20 UR - https://doi.org/10.1109/42.921477 DO - 10.1109/42.921477 ID - de Pierro2001 ER - TY - BOOK PY - 2012 DA - 2012// TI - Quantitatively accurate image reconstruction for clinical whole-body PET imaging ID - ref38 ER - TY - BOOK AU - Ma, H. AU - Asma, E. AU - Ahn, S. AU - Ross, S. AU - Manjeshwar, R. AU - Wilson, D. PY - 2013 DA - 2013// TI - Clinical evaluation of penalized likelihood reconstruction in whole-body PET studies ID - Ma2013 ER - TY - JOUR AU - Passalaqua, S. AU - Kappadath, S. AU - Branch, D. AU - Ross, S. AU - Stearns, C. AU - Schomer, D. PY - 2014 DA - 2014// TI - Qualitative and quantitative evaluation of regularized PET image reconstruction JO - J Nucl Med VL - 55 ID - Passalaqua2014 ER - TY - JOUR AU - Boellaard, R. AU - Krak, N. C. AU - Hoekstra, O. S. AU - Lammertsma, A. A. PY - 2004 DA - 2004// TI - Effects of noise, image resolution, and ROI definition on the accuracy of standard uptake values: a simulation study JO - J Nucl Med VL - 45 ID - Boellaard2004 ER - TY - JOUR AU - Burger, I. A. AU - Huser, D. M. AU - Burger, C. AU - von Schulthess, G. K. AU - Buck, A. PY - 2012 DA - 2012// TI - Repeatability of FDG quantification in tumor imaging: averaged SUVs are superior to SUVmax JO - Nucl Med Biol VL - 39 UR - https://doi.org/10.1016/j.nucmedbio.2011.11.002 DO - 10.1016/j.nucmedbio.2011.11.002 ID - Burger2012 ER - TY - JOUR AU - Afshar-Oromieh, A. AU - Avtzi, E. AU - Giesel, F. L. AU - Holland-Letz, T. AU - Linhart, H. G. AU - Eder, M. PY - 2015 DA - 2015// TI - The diagnostic value of PET/CT imaging with the 68Ga-labelled PSMA ligand HBED-CC in the diagnosis of recurrent prostate cancer JO - Eur J Nucl Med Mol Imaging VL - 42 UR - https://doi.org/10.1007/s00259-014-2949-6 DO - 10.1007/s00259-014-2949-6 ID - Afshar-Oromieh2015 ER - TY - JOUR AU - Heusser, T. AU - Mann, P. AU - Rank, C. M. AU - Schafer, M. AU - Dimitrakopoulou-Strauss, A. AU - Schlemmer, H. P. PY - 2017 DA - 2017// TI - Investigation of the halo-artifact in 68Ga-PSMA-11-PET/MRI JO - PLoS One VL - 12 UR - https://doi.org/10.1371/journal.pone.0183329 DO - 10.1371/journal.pone.0183329 ID - Heusser2017 ER - TY - JOUR AU - Flavell, R. AU - Deller, T. AU - Lake, S. AU - Carroll, P. AU - Hope, T. PY - 2017 DA - 2017// TI - Scatter artifact with 68Ga PSMA-PET: severity reduced with furosemide diuresis and improved time-of-flight scatter correction JO - J Nucl Med VL - 58 ID - Flavell2017 ER - TY - STD TI - Wangerin KA, Baratto L, Khalighi MM, Hope TA, Gulaka PK, Deller TW, et al. Clinical evaluation of (68)Ga-PSMA-II and (68)Ga-RM2 PET images reconstructed with an improved scatter correction algorithm. AJR Am J Roentgenol. 2018:1–6. https://doi.org/10.2214/AJR.17.19356. [Epub ahead of print]. ID - ref46 ER - TY - STD TI - Pizzuto DA, Muller J, Muhlematter U, Rupp NJ, Topfer A, Mortezavi A, et al. The central zone has increased (68)Ga-PSMA-11 uptake: “Mickey Mouse ears” can be hot on (68)Ga-PSMA-11 PET. Eur J Nucl Med Mol Imaging. 2018;45(8):1335-43. https://doi.org/10.1007/s00259-018-3979-2. Epub 2018 Mar 9. ID - ref47 ER - TY - JOUR AU - Puri, T. AU - Greenhalgh, T. A. AU - Wilson, J. M. AU - Franklin, J. AU - Wang, L. M. AU - Strauss, V. PY - 2017 DA - 2017// TI - [18F]Fluoromisonidazole PET in rectal cancer JO - EJNMMI Res VL - 7 UR - https://doi.org/10.1186/s13550-017-0324-x DO - 10.1186/s13550-017-0324-x ID - Puri2017 ER - TY - JOUR AU - Silva-Rodriguez, J. AU - Tsoumpas, C. AU - Dominguez-Prado, I. AU - Pardo-Montero, J. AU - Ruibal, A. AU - Aguiar, P. PY - 2016 DA - 2016// TI - Impact and correction of the bladder uptake on 18 F-FCH PET quantification: a simulation study using the XCAT2 phantom JO - Phys Med Biol VL - 61 UR - https://doi.org/10.1088/0031-9155/61/2/758 DO - 10.1088/0031-9155/61/2/758 ID - Silva-Rodriguez2016 ER - TY - JOUR AU - Mehranian, A. AU - Zaidi, H. PY - 2015 DA - 2015// TI - Impact of time-of-flight PET on quantification errors in MR imaging-based attenuation correction JO - J Nucl Med VL - 56 UR - https://doi.org/10.2967/jnumed.114.148817 DO - 10.2967/jnumed.114.148817 ID - Mehranian2015 ER - TY - JOUR AU - Leynes, A. P. AU - Yang, J. AU - Shanbhag, D. D. AU - Kaushik, S. S. AU - Seo, Y. AU - Hope, T. A. PY - 2017 DA - 2017// TI - Hybrid ZTE/Dixon MR-based attenuation correction for quantitative uptake estimation of pelvic lesions in PET/MRI JO - Med Phys VL - 44 UR - https://doi.org/10.1002/mp.12122 DO - 10.1002/mp.12122 ID - Leynes2017 ER -