Skip to main content

Table 1 Model parameters and start values of the fitting parameters

From: Dependence of treatment planning accuracy in peptide receptor radionuclide therapy on the sampling schedule

Parameter

Standard approach

Iterative approach

R K [nmol]

1.4a

2.1 ± 0.8b

R L [nmol]

2.1a

1.8 ± 0.7b

R S [nmol]

3.8a

3.5 ± 3.1b

R R [nmol]

6.4a

7.3 ± 2.5b

V T [l]

0.3a

0.2 ± 0.3b

f T [ml/min/g]

0.2 ± 0.1b

0.25 ± 0.06b

f ex [%]

96 ± 1.0b

96c

GFR [ml/min]

57.4a

64.4 ± 15.1b

λ deg,T [10−4/min]

1.1a

1.5 ± 0.6b

λ deg,K [10−4/min]

1.1 ± 0.1b

1.1c

λ deg,L [10−4/min]

0.5 ± 0.1b

0.5c

λ deg,S [10−4/min]

1.6 ± 0.1b

1.6c

λ deg,R [10−4/min]

1.3 ± 0.1b

1.3c

# of fitting parameters

13

8

  1. aAdjustable parameters
  2. bBayes parameters with mean ± SD
  3. cFixed parameter values