Table 2 Simulation measurements

From: Gating, enhanced gating, and beyond: information utilization strategies for motion management, applied to preclinical PET

Relative counts in image space 1 4 13 55 2,000
Maximum  
Ungated 94 82 78 75 74
Gated 219 146 122 108 100
Gating+ 95 125 115 108 100
Volume (70% maximum)  
Ungated 57 144 177 194 199
Gated 6 17 49 84 99
Gating+ 55 41 76 89 103
SUV (mean VOI/background)  
Ungated 91 77 74 73 72
Gated 249 153 118 104 100
Gating+ 92 122 110 105 100
FWHM  
Ungated 144 174 183 187 188
Gated 38 68 90 98 100
Gating+ 143 88 96 94 100
  1. Summary of lesion measurements from simulations of hot lesion against colder background with a range of random noise levels added (see Figure 5). Numbers represent average measurements from a single gate of 500 simulations for each noise scenario. All measurements are presented as a percentage of the corresponding true noise-free values. The standardized uptake value (SUV) was calculated from for 70% threshold volume.