Skip to main content

Table 1 〈z〉 and 〈z1data for single thyroid follicle models depend on source compartment

From: Microdosimetric analysis of 211At in thyroid models for man, rat and mouse

 

Nucleus ← Nucleus

Nucleus ← Follicle cells

Nucleus ← Lumen

 

〈z〉 and 〈z1(Gy)

〈z〉 (Gy)

〈z1(Gy)

〈z〉 (Gy)

〈z1(Gy)

Mouse

5.36E-1

2.74E-3

1.01E0

2.03E-3

1.25E0

(1.13E-4)

(1.91E-5)

(3.48E-3)

(1.76E-5)

(4.67E-3)

Rat

2.40E-1

1.40E-3

4.60E-1

1.08E-3

6.14E-1

(5.07E-5)

(9.38E-6)

(1.61E-3)

(9.12E-6)

(2.33E-3)

Man

1.36E-1

3.17E-4

2.57E-1

1.71E-4

3.70E-1

(2.86E-5)

(3.36E-6)

(1.42E-3)

(2.83E-6)

(2.79E-3)

  1. The mean specific energy, 〈z〉, and the single-hit mean specific energy, 〈z1〉 for the mouse, rat and human models per decay. 211At was homogeneously distributed within the source volume (nucleus, follicle cells or lumen), and the target was the follicle cell nucleus. Note: data are given as mean (SD).