From: Suitability of bilateral filtering for edge-preserving noise reduction in PET
Lesion | Volume (mL) | SUVmax orig. | SUVmax MAF | SUVmax BF |
---|---|---|---|---|
1 | 1.2 | 6.3 | 4.1 | 5.9 |
2 | 1.9 | 5.0 | 2.8 | 4.7 |
3 | 1.9 | 5.8 | 3.3 | 5.6 |
4 | 2.4 | 4.0 | 2.3 | 3.5 |
5 | 2.9 | 5.4 | 3.7 | 5.1 |
6 | 3.2 | 23 | 17 | 22 |
7 | 3.4 | 6.9 | 4.5 | 6.5 |
8 | 3.7 | 7.0 | 4.8 | 6.6 |
9 | 3.7 | 7.3 | 5.1 | 6.9 |
10 | 4.3 | 17 | 14 | 17 |
11 | 4.4 | 9.8 | 7.7 | 9.5 |
12 | 4.7 | 17 | 11 | 16 |
13 | 4.8 | 6.8 | 5.6 | 6.2 |
14 | 5.1 | 13 | 8.8 | 12 |
15 | 5.2 | 3.3 | 2.5 | 2.7 |
16 | 5.5 | 18 | 15 | 17 |
17 | 6.4 | 5.8 | 3.6 | 5.6 |
18 | 6.9 | 6.8 | 4.5 | 6.2 |
19 | 7.0 | 20 | 15 | 20 |
20 | 7.5 | 20 | 16 | 20 |
21 | 8.4 | 8.4 | 6.3 | 8.0 |
22 | 11 | 13 | 9.5 | 12 |
23 | 11 | 12 | 9.1 | 12 |
24 | 14 | 6.8 | 5.4 | 6.3 |
25 | 23 | 18 | 15 | 17 |
26 | 29 | 8.7 | 7.4 | 8.1 |
27 | 30 | 21 | 19 | 20 |
28 | 34 | 11 | 9.3 | 11 |
29 | 49 | 17 | 16 | 17 |
30 | 56 | 27 | 24 | 27 |
31 | 62 | 10 | 8.4 | 9.5 |
32 | 81 | 14 | 11 | 14 |
33 | 99 | 16 | 14 | 16 |
34 | 103 | 26 | 23 | 26 |